Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Healthcare (Basel) ; 9(2)2021 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-33562102

RESUMO

This study aimed to evaluate the effectiveness of using ultrashort implants in the rehabilitation of jaws of fragile patients. The aim of the study was to retrospectively evaluate the survival rate of full-arch prosthetic rehabilitation on ultrashort implants, length 4 mm, 4 mm in diameter in the premolar and canine area and 4.5 mm in diameter in the molar area, with the insertion torque of 60 Nw and immediate loading. Nineteen patients were evaluated for 3 years clinically and radiographically. The significant majority of the patients at the 3 year follow-up (T4) presented a stable and functional implant-supported prothesis, and the survival rate of the implants was 85%, with a loss of 16 implants on 114 implants. The combination of the innovative implant surfaces and the correct project of the prostheses, with the related implant connection, determined a different timing in the therapy, allowing to obtain an immediate loading, which is currently demanded by patients. This and recent reports on short and ultrashort implant usage in atrophic jaws offer a good solution in critical cases. In conclusion, within the limits of the study, the full-arch rehabilitation with immediate loading on ultrashort implants showed good results with few postoperative complications and related low biological cost.

2.
J Oral Implantol ; 44(3): 184-191, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29436942

RESUMO

The aim of this study was to evaluate the reliability of 6-mm-long implants compared with normal-length implants placed in a vertical augmented atrophic posterior mandible, supporting cemented single crowns. Thirty-six patients with bilateral posterior edentulous mandible and presenting a bone availability height less than 9 mm from the mandibular canal were enrolled in this study. Patient hemiarches were randomized to receive both 6-mm-long and normal-length implants (10 mm). The technique used for the vertical bone augmentation was the "sandwich" technique, using a bone substitute block as graft. The data outcomes at 1 year postloading follow-up were the loss of implants and complications. Eighty-six 6-mm-long implants and 84 normal implants were inserted. Five short implants and 13 normal implants were lost. In 28 patients, complications occurred, and in 21 cases, the complication was present on the side of the ridge vertical augmentation. From the statistical analysis, the association between the side of the ridge augmentation and the side of occurrence of the complication was statistically significant ( P < .05). The results from this trial suggest short implants can be preferred over vertical bone augmentation for the placement of longer implants in the rehabilitation of edentulous posterior mandibles. These initial results must be confirmed by larger and longer follow-ups of 5 years or more.


Assuntos
Aumento do Rebordo Alveolar , Substitutos Ósseos , Implantes Dentários , Aumento do Rebordo Alveolar/métodos , Transplante Ósseo , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Seguimentos , Humanos , Mandíbula , Boca , Reprodutibilidade dos Testes , Resultado do Tratamento
3.
Med. oral patol. oral cir. bucal (Internet) ; 22(2): e201-e206, mar. 2017. tab, graf
Artigo em Inglês | IBECS | ID: ibc-161237

RESUMO

BACKGROUND: The attainment of a good primary stability is a necessary condition to ensure the success of osseointegration in implantology. In type IV cancellous bone, however, it is possible that a reduced primary stability can lead to an increased rate of failure. The aim of this study was therefore to determine, with the help of the resonance frequency (Osstell mentor), which technique of implant site preparation (piezo surgery, conventional, under-preparation, bone compaction, osteodistraction) and macro-geometry is able to improve implant stability in type IV cancellous bone. MATERIAL AND METHODS: 10 pig ribs were prepared with a surgical pre-drilled guide, calibrated for a correct implant positioning. On each rib, 5 implant sites (one for each technique) were prepared. Successively, 50 conical implants (Tekka Global D) were inserted and measured with the resonance frequency to evaluate the primary stability. Data collected were analyzed by analysis of variance (ANOVA) to test whether the Implant Stability Quotient (ISQ) values of the five techniques were significantly different. RESULTS: The results showed that no significant differences among the ISQ values of the five techniques used were found. Also, no significant differences in the macro-geometry of the two types of compared implants were observed. However, the macro-geometry of Tekka implants, characterized by a double condensing thread, seems to provide greater ISQ values than those of single thread implants when using the same technique. CONCLUSIONS: In light of these preliminary data, it is conceivable that in cases of reduced stability, such as those occurring with a type IV bone, all means ameliorating the primary stability and accelerating the osseointegration can be utilized


Assuntos
Humanos , Implantação Dentária Endóssea/métodos , Osseointegração/fisiologia , Técnicas In Vitro/métodos , Cuidados Pré-Operatórios/métodos , Interface Osso-Implante
4.
Int J Immunopathol Pharmacol ; 29(4): 778-783, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27106276

RESUMO

INTRODUCTION: Studies on biomaterials involve assays aimed to assess the interactions between the biomaterial and the cells seeded on its surface. However, the morphology of biomaterials is heterogeneous and it could be tricky to standardize the results among different biomaterials and the classic plastic plates. In this light, we decided to create, by means of computer-aided design (CAD) technology, a standardized sample model, with equal shape and sizes, able to fit into a classic shape of a 96-wells tissue culture plate (TCP). METHODS: The design of this sample consists of a hole in the top in order to allow the injected cells to settle without them being able to slip from the sides of the sample to the bottom of the TCP wells. This CAD project is made using the software Pro-Engineer. The sample will totally fill the wells of the 96-well TCP. Dental pulp stem cells have been used to assess the ability of the different sample to support and promote the cell proliferation. RESULTS: Twelve titanium, 12 gold-palladium, and 12 zirconium oxide customized samples were designed by means of the software cam powermill, by importing the .stl file created in Pro-Engineer software. The proliferation rate of the tested scaffolds showed to be similar to the control in the group with the customized shape. CONCLUSION: We think that our method can be useful to test different types of scaffolds when a greater accuracy of the measurements is desirable in order to verify the cell behavior of these scaffolds. Our innovative method can improve the standardization process in the evaluation of cell behavior on different biomaterials to open the way to more reliable tests on biomatrices functionalized with drugs or growth factors applied to the future regenerative medicine.


Assuntos
Materiais Biocompatíveis/farmacologia , Medicina Regenerativa/métodos , Tecidos Suporte/química , Adulto , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Desenho Assistido por Computador , Polpa Dentária/efeitos dos fármacos , Humanos , Teste de Materiais/métodos , Paládio/farmacologia , Células-Tronco/efeitos dos fármacos , Titânio/farmacologia , Zircônio/farmacologia
5.
Int J Immunopathol Pharmacol ; 29(1): 3-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26612837

RESUMO

Tissue engineering applications need a continuous development of new biomaterials able to generate an ideal cell-extracellular matrix interaction. The stem cell fate is regulated by several factors, such as growth factors or transcription factors. The most recent literature has reported several publications able to demonstrate that environmental factors also contribute to the regulation of stem cell behavior, leading to the opinion that the environment plays the major role in the cell differentiation.The interaction between mesenchymal stem cells (MSCs) and extracellular environment has been widely described, and it has a crucial role in regulating the cell phenotype. In our laboratory (Tecnologica Research Institute, Crotone, Italy), we have recently studied how several physical factors influence the distribution and the morphology of MSCs isolated from dental pulp, and how they are able to regulate stem cell differentiation. Mechanical and geometrical factors are only a small part of the environmental factors able to influence stem cell behavior, however, this influence should be properly known: in fact, this assumption must be clearly considered during those studies involving MSCs; furthermore, these interactions should be considered as an important bias that involves an high number of studies on the MSCs, since in worldwide laboratories the scientists mostly use tissue culture plates for their experiments.


Assuntos
Matriz Extracelular/fisiologia , Células-Tronco Mesenquimais/fisiologia , Humanos , Técnicas de Cultura de Tecidos , Engenharia Tecidual
6.
Anat Res Int ; 2014: 906348, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25215238

RESUMO

In descriptions of surgical procedures in mandible, often there is no mention of an anatomical variance, the genial spinal foramina, where nerves and vessels go through. Aim of this study is to investigate frequency, shape, and dimensions of these foramina. 56 computed tomography dentascans were analyzed with an implant planning software. The considered parameters were frequency, number, position, diameters, and length of canals; the collected data were inserted in a spreadsheet and statistically analyzed; therefore, they were compared with those found in the literature. The measurements agree with the ones found in earlier studies, except for the length of the inferior spinal canals, which resulted lesser than that found in the literature. The frequency of the inferior spinal foramina, the data related to the inferior spinal foramina diameter (cross scan), and the measurements related to the superior spinal foramina diameter (axial scan) resulted to be major compared to those reported in literature. These obtained results are clinically interesting because an implant planning software has been employed, daily used by operators, and that permits in vivo investigations. Furthermore, due to the possibility of hemorrhagic accidents in this mandibular region, these data are particularly interesting for all of the operators who make interventions in this area.

7.
Expert Opin Drug Saf ; 13(10): 1319-26, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25195948

RESUMO

INTRODUCTION: Sleep and awake bruxism is defined as 'a parafunctional activity including clenching, bracing, gnashing, and grinding of the teeth'. Some evidence suggests that bruxism may be caused by, or associated with, alterations in the CNS neurotransmission. Several classes of psychotropic drugs interfering with CNS activity may potentially contribute to bruxism. Thus, the purpose of this study was to examine relevant peer-reviewed papers to identify and describe the various classes of psychotropic substances that may cause, exacerbate or reduce bruxism as the result of their pharmacological action in CNS neurons. AREAS COVERED: A literature search from 1980 to the present was performed using PubMed database. The term 'bruxism' was used in association with 'psychotropic', 'dopamine (DA)', 'serotonin', 'histamine', 'antipsychotics', 'antidepressants', 'antihistaminergics' and 'stimulants'. EXPERT OPINION: Studies on the effects of DA agonists (Levo-DOPA, psychostimulants) and antagonists (antipsychotics) identified a central role of DA in the pathogenesis of pharmacologically induced bruxism. Important information from studies on drugs acting on serotonin neurotransmission (antidepressants) was recognized. Other mechanisms involving different neurotransmitters are emerging. This is the case of antihistaminergic drugs which may induce bruxism as a consequence of their disinhibitory effect on the serotonergic system.


Assuntos
Bruxismo/induzido quimicamente , Psicotrópicos/efeitos adversos , Bruxismo do Sono/induzido quimicamente , Animais , Antidepressivos/efeitos adversos , Antidepressivos/farmacologia , Bruxismo/epidemiologia , Dopamina/metabolismo , Agonistas de Dopamina/efeitos adversos , Antagonistas de Dopamina/efeitos adversos , Antagonistas dos Receptores Histamínicos/efeitos adversos , Antagonistas dos Receptores Histamínicos/farmacologia , Humanos , Psicotrópicos/farmacologia , Serotonina/metabolismo , Bruxismo do Sono/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...